Suction pressure for 410a - Head on 410 at 100° will be in the 375 - 400 range depending on surrounding conditions, sun, heat load inside, dirt on the coil. high suction pressure could be from a high load, bad compressor, bad-wrong-nonexistant metering device. There are a multitude of things that can cause pressures to be high or low depending on the situation.

 
The high head probably due to the other guys overcharging, trying to get the suction pressure up. But the low air problem would result in high head pressure in the heat cycle. If the contactor is actually dropping out, I would guess a hi/lo pressure limit opening. Reply . 01-01-2012, 10:14 AM #8.. How to enter referral code on cash app

Nov 11, 2022 · 2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2. High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps.Mar 26, 2024 · The low side pressure of a typical R410A mini split is between 110-140 psi depending on the operating conditions. Though it can vary, the low side pressure of a mini split should not fall below 100 psi or raise beyond 160 psi. The working pressure of mini splits is depending on factors such as the weather and cooling load. r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3I am wondering what the high and low pressures should be in a 3-ton 410a refrigerant AC system. The installer seemed - Answered by a verified HVAC Technician ... .If the room was at 78 (round to 80) and if the coil was running 25 degrees colder (i.e. 55 degrees), we would see a suction pressure of 155 psig.Since the room was at 84 …I would think we could have a thermostat that could do this: Heating mode: outside temp >65F: Run AUX only - lock out compressor (avoid high pressure) outside temp >10F and <65F: Run compressor and AUX as needed. outside temp <10F: Run AUX only - lock out compressor (avoid defrost cycling) Cooling mode: outside temp <60F: lock … Constants for vapor pressure of saturated vapor (dew point), p g: A = –1.440004 E+00 E = –3.521484 E+00 B = –6.865265 E+00 F = –7.750000 E+00 C = –5.354309 E–01 X o = 2.086902 E–01 D = –3.749023 E+00 Because both pressure and temperature appear in the reduced form in the equation, the same constants can be used for either SI or ... R-410A refrigiant. The Suction pressure temperature chart in the Condensing Unit installation & service reference that came with the unit only goes up to 80 psig, yet I'm seeing 135 psig at the low side service valve. Looking elwhere I found that 135 psig is 47F. High side 285 psig which is 92F. Spec is SH 7-9F and SC 7-9F (using TXV). SC: 92F ...May 21, 2021 ... 410A single refrigerant PT chart here https://www.es-refrigerants.com/docs/29132_585.pdf Esco Chart here ...The R410A PT chart can be used to answer questions like: What are normal operating pressures for 410A? What is the pressure of r410a at 72 degrees Fahrenheit? What should gauge read for 410A? You can also use the R …Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is ____ than R-22. A. Higher B. Lower C. The same D. None of the above, R-410A is also known as: A. Suva 410A B. AZ-20 C. Puron D. All the above, Both suction and discharge pressures of R410a systems are … Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is _____ than R22, Both suction and discharge pressures of R-410A systems are _____ than R-22 systems, The temperature glide for R-410A is less than _____ degrees Fahrenheit over air conditioning and refrigerating operating ranges and more. Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.Jul 8, 2019 · High Suction Pressure R-410a. i went to check an 3.5 ton a/c brand is a ICP (international comfort products) Model WAPL424A1, not cooling my pressures were low side 185 to 190 and high side was around 350 on a 107F hot day. It has a piston as a metering device and compressor was running at 11.50 amps and RLA is 17.25 amps. These liquid-line restrictions all cause the evaporator, compressor, and condenser to be starved of refrigerant. This will cause the following symptoms: Low evaporator (suction) pressure; High evaporator and compressor superheats; Low compressor amp draw; Short-cycling on the low-pressure control;These line sizing charts are based on a suction pressure drop equivalent to a 2°F change in saturation pressure and liquid line pressure drop of 5 psi. For R-404A Low Temperature 1 psi; for R-404A and R-22 Medium Temperature 2 psi is used. This is the maximum allowable pressure drop for the entire piping run regardless if it is 50' or 250'.Theoretical calculations reveal that at the above high-temperature cooling conditions, a 2-psi suction pressure drop produces about 2% loss of efficiency and 2.4% loss of capacity in an R-22 system. But in an R-410A system, the suction pressure drop can be allowed to go as high as 3.1 psi before the same losses in performance are seen.Some people have low blood pressure (hypotension). It is only a problem if it causes dizziness, fainting, or shock. Learn about what can cause it. You've probably heard that high b...I checked the unit it showed to be low of charge when adding 410a suction line temp keeps going up.What am I doing wrong Reply . 06-03-2015, 03:43 PM #2. lkapigian. View Profile ... I thinks your assuming it was low because of suction pressure. If TXV Charge to sub cooling-- I am thinking your sub cooling was high and you have a …Find out what causes high suction pressures and the consequences of high suction pressure. We examine the refrigeration cycle and work to solve the root of high suction pressure 410a problems. Read more with HVAC Brain. ... 1.5 - 3 TON TXV R410A) Table 1: R134a Saturation Properties pressure table (Reference: …This system uses R-410A refrigerant, which operates at higher pressures than R-22. No other refrigerant may be used in this system. Gauge sets, hoses, refrigerant containers, and the recovery system must be designed to handle R-410A. If you are unsure, consult the equipment manufacturer. WARNING Never install a suction-line filter-drier in the ...What is the r410a’s suction and discharge pressure? R-410A, a new refrigerant that has recently been developed, is currently being used in the HVAC/R industry. As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A.Theoretical calculations reveal that at the above high-temperature cooling conditions, a 2-psi suction pressure drop produces about 2% loss of efficiency and 2.4% loss of capacity in an R-22 system. But in an R-410A system, the suction pressure drop can be allowed to go as high as 3.1 psi before the same losses in performance are seen.SUCTION PRESSURE / EVAP DTD RULE OF THUMB Another common old school rule of thumb is suction pressure should be close to the outdoor temperature in a R-22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient.Suction Pressure/EVAP DTD Rule of Thumb Another common old-school rule of thumb is that suction pressure should be close to the outdoor temperature in an R22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20°-25° suction saturation below outdoor ambient.Study with Quizlet and memorize flashcards containing terms like Because of its higher vapor heat capacity, the discharge temperature of R-410A is _____ than R22, Both suction and discharge pressures of R-410A systems are _____ than R-22 systems, The temperature glide for R-410A is less than _____ degrees Fahrenheit over air conditioning and refrigerating operating ranges and more.With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page.Technical Guide: R-410A Outdoor Split- System Heat Pump - RHP143. York International Corporation, 5005 York Drive, Norman, OK 73069. 2022-10-05 6231804-UTG-A-1022 Supersedes: nothing. 2 Technical Guide: R-410A Outdoor Split-System Heat Pump - RHP143 Johnson Controls Ducted Systems.Aug 5, 2023 · Read also: R410a Pressure Chart High and Low Side. psi: Pound per square inch, unit of pressure. FAQ What is the normal suction pressure on a 404a walk in the freezer? The normal suction pressure on a 404 a walk in freezer is around 10-20 psig (10 is ideal) on the suction side if working properly. And the high side is about 180 or so. 1. Optimal Cooling. When the low side pressure operates within the recommended range for 410a, your system can efficiently absorb heat from your indoor environment. Any deviation from this range might compromise the cooling efficiency, leaving certain areas less cooled than others. 2.What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system.Typically, for a properly charged R-410A system, the low-side (suction) pressure may range from 120 to 150 psi, and the high-side (discharge) pressure may …For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 compressor can replace with R410A. by Mohammed Awais haji Latif.SUCTION PRESSURE / EVAP DTD RULE OF THUMB Another common old school rule of thumb is suction pressure should be close to the outdoor temperature in a R-22 system. However, this rule of thumb (obviously) does not work on an R-410A system. A more applicable guideline is 20˚-25˚ suction saturation below outdoor ambient.May 8, 2017 · Find out what causes high suction pressures and the consequences of high suction pressure. We examine the refrigeration cycle and work to solve the root of high suction pressure 410a problems. Read more with HVAC Brain. Making changes to your diet is a proven way to help control high blood pressure. These changes can also help you lose weight and lower your chance of heart disease and stroke. Maki...’ve highlighted 117 PSIG in the chart above. It’s a ballpark figure of where the suction pressure could be on an R-454B system. The P-T chart tells us that the suction saturation temperature (SST) for an R-410A system is 39.4°F at that pressure. R-32 is very close behind at 38.3°F. R-454B is a little higher at 44.6°F.r-410a pressure temperature chart psig f° psig f° psig f° psig f° psig f° psig f° 12 -37.7 114 37.8 216 74.3 318 100.2 420 120.7 522 137.6 14 -34.7 116 38.7 218 74.9 320 100.7 422 121 524 137.9 16 -32.0 118 39.5 220 75.5 322 101.1 424 121.4 526 138.3psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114May 5, 2016 · The SC might be normal , but the normal head for a r410 system w/ a 68* ambient should be closer to 300psi and the normal suction press should be closer to 110psi w/70* IDB. Those p/t's sound more like r22. kdean1, buttwheat liked this post. As others have said it sounds like a TXV and maybe low on juice. Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the components that make up Freon™ 407C and Freon™ 410A. Table 1. Components of Freon™ 407C: HFC-32/HFC-125/HFC-134a and Freon™ 410A: HFC-32/HFC-125Freon™ 410A (R-410A), wt% 50 50 — Because Freon™ 407C and Freon™ 410A are mixtures of HFCs, they have zero ODP. Table 1 lists the chemical names and formulae of the components that make up Freon™ 407C and Freon™ 410A. Table 1. Components of Freon™ 407C: HFC-32/HFC-125/HFC-134a and Freon™ 410A: HFC-32/HFC-1251. Optimal Cooling. When the low side pressure operates within the recommended range for 410a, your system can efficiently absorb heat from your indoor environment. Any deviation from this range might compromise the cooling efficiency, leaving certain areas less cooled than others. 2.The normal pressure for a typical R-401A mini-split ranges from 110-140 psi. However, keep in mind that the working pressure depends on factors like cooling load and weather. …Nov 11, 2022 · 2. Record the temperature and measure the suction pressure at the suction lines. 3. Convert the suction pressure recorded to the temperature using the temperature/ pressure Chart. 4. To calculate superheat simply subtract the two temperature values. IMPORANT: In most systems. 1. Superheat is about 10 degrees when measured at the evaporator and. 2. What should be the 410a suction pressure? As shown in Figure 1 on the next page, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi with R-410A. HFC-32 and HFC-125 are mixed together in R-410A, which is an azeotropic mixture.SUBJECT: TEMPERATURE - PRESSURE CHART FOR FYI #289 9/17/2009 R-22, R-410A, R-407C, R-134A & R-404A REFRIGERANTS ADVANTAGE Engineering, Inc.525 East Stop 18 Road Greenwood, IN 46142 317-887-0729 fax: 317-881-1277 web site: www.AdvantageEngineering.com email: [email protected]. R-410A compatibility offered with P266SNR-2C transducer PRODUCT SWITCH ACTION BOTTOM OF RANGE TOP OF RANGE MAXIMUM WORKING PRESSURE TYPICAL APPLICATIONS P70 SERIES ADJUSTABLE ON/OFF PRESSURE CONTROLS P70AA-2C SPST Open Low 0 150 325 Suction pressure control — loss of charge P70AA-400C SPST Open Low 100 470 690 Fan cycling for head pressure ...1. Even though this is not the cause of high suction, Clean The Evaporator, because it needs to be clean. If it's dirty, it causes LOW suction pressure, and causes inexperienced techs to overcharge a system. 2. Just for kicks, and for a learning experience, check the system vitals, and record the pressures, water temp entering and leaving the ...When it comes to choosing a hand held vacuum, there are several factors that determine its strength and effectiveness. From suction power to battery life, each feature plays a cruc...And other quick methods to relieve your sinus pressure. Blocked sinuses are no fun—especially during a pandemic, when every single seasonal sniffle or sinus headache results in a n...Making changes to your diet is a proven way to help control high blood pressure. These changes can also help you lose weight and lower your chance of heart disease and stroke. Maki...In this HVAC Training Video, I Show If You Can Check The Refrigerant Charge on an Inverter Mini-Split Ductless Unit on a Service Call by measuring superheat ...Nov 16, 2020 · What is the vapor pressure of the R-410A? The vapor pressure is 118 PSIG and because it is 85°F outside, the R-410A bottle pressure is 254 PSIG. The pressure in the bottle is much higher than the pressure on the low side of the system so if they are connected, refrigerant will exit the bottle and enter the system. liquid and suction lines covering total linear = 200 ft. equivalent lengths up to 240 ft. The philosophy in designing a refrigerant piping system can be summed up as follows: Liquid lines should be sized as small as possible without exceeding the recommended maximum pressure drop of 50 PSI for R-410A. Liquid line pressure When the refrigerant is flowing in the suction line from the compressor to evaporator coil without any leakage or damaging the compressor’s piston and also there no impurities are present then the pressure range will be inside the system is 0.75 – 1.3 MP ,this called the High suction pressure normal head pressure.psig °f psig °f psig °f psig °f psig °f 12; –37.7. 114With 410a heat pumps is there a recommended suction pressure. For example with R22 air-con systems I always aim for 400 suction and 1500 discharge and similar with 407c systems. I have been told to aim for round the 100 psi/700kpa mark with is about 0 degree C Was just curious for fault finding purposes. Cheers in advance, chris.The pressure of R-410A is so high that if your hand gets in the way of a leak, it could cut a finger off. This is a myth, as well as a physical impossibility. Devices such as insulin jet injectors require 7,000 to 10,000 psi pressures to puncture the skin and 16,000 to 25,000 psi pressure spikes are normally used.The recommended high-pressure control settings are a cut-out pressure of 610 psig and a cut-in pressure of approximately 500 psig. The recommended low …I installed a new 410a complete system with new Orfice coil and new lineset. 70 degrees on install date and initial start up. Suction pressure was 110 and high side of 280. It ran for about 15 minutes. I added a little freon and the high side shot up to 425.What should my gauge readings be on 410a on 95 degrees at condenser. looking at pt chart at 95 degrees shows 295 is - Answered by a verified HVAC Technician. ... The liquid pressure should be 385-395 and the suction pressure should be about 138 but will probably be a few psi lower since it's so cool in the space. The sub …High Suction Pressure! I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI and my sub-cooling is around 40-50 Degrees. I have checked for a stuck liquid line solenoid but this system does not have one, and I checked the reversing valve and ...1. Optimal Cooling. When the low side pressure operates within the recommended range for 410a, your system can efficiently absorb heat from your indoor environment. Any deviation from this range might compromise the cooling efficiency, leaving certain areas less cooled than others. 2.The condenser comes charged with 15 feet of 410A. My install has 40 feet of 3/8" and 7/8" line total --- leaving 25 feet needing additional refrigerant. (Goodman suggest adding .6 oz per foot of liquid line) but that seems to be high. At the present time I am setting at 308 (High Side and 143 Low Side with no charge added beyond the 15 foot ...On a properly functioning R-22 system running in heat mode in 40-degree weather, the suction pressure tends to be around 40 PSIG. This guideline obviously doesn't work on an R-410A system or any other refrigerant. A more applicable guideline is 20-25˚ suction saturation below outdoor ambient temperature. After the suction line has been strapped to the joist or rafter at 8’ (2.4 m) intervals, strap the liquid line to the suction line. 8’ (2.4 m) Metal Sleeve Wire Tie (around suction line only) Floor Joist or Roof Rafter Tape or Wire Tie Tape or Wire Tie If hanging line set from a joist or rafter, use metal strapping or heavy nylon wire tires Suction pressure R410A. I ran a system today and had a suction pressure of 5 bar. I have never seen one so low on 410A and charged to manufacturers guidelines, there was frosting on suction valve and inlet/outlets to evap after a couple of minutes. Acson A5LC25CR-ACPOC-R outdoor unit connected to AHU.The blue hose connects to the service port on the unit and then the yellow hose connects to your vacuum pump. The blue hose is 5/16 in. ready to connect to the outdoor unit. The yellow is 1/4 in. for most vacuum pumps. The depicted valve isolates the gauge itself. This gauge also comes with a diagram on the packaging box.May 21, 2021 ... 410A single refrigerant PT chart here https://www.es-refrigerants.com/docs/29132_585.pdf Esco Chart here ...I have a 3Ton Carrier Heat Pump unit using 410A that has extremely high suction pressure around 250PSI. I also have a low liquid line pressure around 300PSI …Typically, for a properly charged R-410A system, the low-side (suction) pressure may range from 120 to 150 psi, and the high-side (discharge) pressure may …to adjust valves when facing adjusting stem clockwise decreases pressure / temperature. counter-clockwise increases pressure / temperature. rawal devices, inc. call tech support: (800) 727-6447 www.rawal.com ©2020 rawal devices, inc. doc#410a-sdsHello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and continue increasing the pressure on both sides almost to 400psi on ...My very wild guess would be an obstruction somewhere in the coil or suction line. You eliminated every other cause for a high low pressure (Air flow, refrigerant, compressor txv). I would try touching and observing the piping for any sudden change in temperature. Student here, so take this with a grain of salt. 2.For air conditioning system, R22 pressure in discharge is250psi and suction in67psi. But for R410A pressure will be more higher that R22. So what pressure is normal for air-conditioning systems. Besides that normal R22 compressor can replace with R410A. by Mohammed Awais haji Latif.So we replace the compressor (same model #), replace the liquid line filter dryer, and evacuate to 500 microns. I weigh the charge in per the manual = unit's orignal charge + addl ounces per foot of lineset - total of 5# 6 oz. Start unit up, damn it, looks wrong immediatelY: Suction: 149.5 psi. Suction Temp: 55.4*F.Hello, I have a Rheem (2015) heat pump 2ton 410A, on cooling mode the system runs great; suction and liquid pressure are ok 185/360, super heat 10 F, with 90F outdoor temperature, now the winter is coming and the system on heating mode the gages read high pressure on both sides, begin from 365 on suction and liquid lines and continue increasing the pressure on both sides almost to 400psi on ...R-410A and R-22 is the higher operating pressures (approximately 50% higher on both the discharge side and the suction side).For example, a high-efficiency condensing unit using R-22 typically operates with a suction pressure of about 68 psi and a discharge pressure of about 250 psi at an outdoor temperature of 95°F.I shouldn't feel so tired. So overwhelmed. So underwhelmed. I shouldn't feel so much pressure. So much guilt. So much anxiety. I shouldn't expect so much from myself...Mini Split 5/16 in. R410a Low Side Suction Charging Service Gauge Hose Set Port ... Low-side charging manifold with R410A low-side pressure gauge; View More Details; Store 0 in stock. Free & Easy Returns In Store or Online. Return this item within 90 days of purchase. Read Return Policy.This script determines the gas pressure based on temperature of R410a refrigerant. R410A is an HFC refrigerant, invented by Honeywell, that has been developed to replace the HCFC refrigerant R22. Systems operating on R410A run at a pressure of about 1.6 times that of similar systems operating on R22. Energy efficiency is comparable to R22.Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ...

™ 410A Refrigerant (R-410A) Replacement for R-13B1: Properties and Operating Characteristics of Freon™410A Refrigerant in Very Low Temperature Systems ... Suction Pressure, kPa (psia) 104 (15) 138 (20) Discharge Pressure 1484 (215) 1470 (213) Discharge Temperature 128 (263) 92 (197). How much is hannity worth

suction pressure for 410a

410a low suction pressure. I injected super seal in a 410a system that had a tiny leak that I could not find. 2 years later I come across the problem of low suction pressure normal head pressure. Replaced txv and had same problem. Replaced compressor and had the same problem. Could the super seal be clogging the txv or evaporator or condenser ...The image above is of the Danfoss refrigerant slider app, and it shows that when suction pressure drops below 102 PSIG on an R410a system, the coil hits 32° and will start to freeze. ... Let's say it's 78° in a house on an R410a system, and your suction pressure is 108 PSIG (as shown). Your suction saturation (coil temperature) is 35°. So ...Typical low pressure or suction side, may vary by equipment and metering controls - these are "gauge pressure readings" or "psig" ... Both older R-22 and R-134 operate at lower pressures than R-410A. R22 Refrigerant Pressure Rules of Thumb Typical Off, Low, High side R22 Pressures & Temperatures.After the suction line has been strapped to the joist or rafter at 8’ (2.4 m) intervals, strap the liquid line to the suction line. 8’ (2.4 m) Metal Sleeve Wire Tie (around suction line only) Floor Joist or Roof Rafter Tape or Wire Tie Tape or Wire Tie If hanging line set from a joist or rafter, use metal strapping or heavy nylon wire tiresBy contacting an HVAC technician, you can get your AC system’s suction pressure back to normal levels. If you are experiencing a problem with your air conditioning or heating call us at 512-336-1431 to schedule an appointment. We’ll be glad to come out and take a look at the issue. 1431-183 A/C & Heating proudly serves Round Rock ...Quick Example: Let’s say that we have a 3-ton 16 SEER AC are using R-410A refrigerant and want to calculate R-410A superheat. With low side blue gauge on the suction line service port, we measured 130 psi pressure that correlates (according to R-410A PT chart) to about 45°F. The clamp-on thermometer shows that the saturated refrigerant ...With R-410A, the same unit will operate under the same conditions with a suction pressure of 118 psi and a discharge pressure of 400 psi, as shown in Figure 1 on the next page.View and Download Rheem R-410A installation instructions manual online. PRL-JEC Series two-stage heat pump outdoor units. R-410A heat pump pdf manual download. Also for: Prl-jec series, 024jec, 036jec, 048jec, 060jec. ... Low Suction Pressure Moisture freezing and blocking valve Recover charge, install filter-drier, evacuate system, ...Never install suction- line filter drier in the liquid- line of an R-410A system.! CAUTION 7. If suction-line filter drier was installed for system clean up, operate system for 10 hr. Monitor pressure drop across drier. If pressure drop exceeds 3 psig, replace suction-line and liquid-line filter driers. Be sure to purge system with dry nitrogen ...R410a unit heat pump. Get to call and unit wont turn on. Customer stats unit runs for five minutes with hot air coming out the starts blowing cold. Check all switches and limits. Find the lower pressure switch open. Jump it go see if unit runs and see what the charge looks like. Unit is running 300/80 in heat mode.Sep 19, 2013 ... This one covers a test of an air conditioner with high return air temperature to determine how high the suction pressure will go.Refrigerant Properties Freon™ 410A vs. R-22 Discharge Pressure +50 to +70% Cooling Capacity +45% Discharge Temperature –10 °F (-23.3 °C) Energy Efficiency +5 to –5% Lubricant POE. Freon™ 410A Refrigerant For more information on ….